A central split heat pump for a 1,248-square-foot lodge in climate zone 16, with tested ducts.
Scope
Ducted split heat pump: wall-mounted outdoor condenser, air handler and ducts in the dropped ceiling (A1.0).
Bath exhaust and ventilation per Title 24.
HERS verifications: refrigerant charge / heat pump, duct leakage, and fan watt draw.
Minimum performance in the energy report: HSPF2 9.5 / SEER2 14.
What to price
- Equipment, ducts (R-8 in the attic, sealed and tested), bath fan, and coordination with the HERS rater.
Plan sheets
- A1.0
- E1.0
- Title 24 report
Documents
Open or download the files for this trade, or the full bid-package folder.
Sequence
Rough-in after framing, before insulation. Testing is part of HERS sign-off.